Skip to content


Making a Difference in Quebec!

3 comments

In April of 2011, Brotherhood Instructors conducted 3 days of "Beyond the Academy: Forcible Entry Operations" training at the IPIQ training facility in Laval Quebec.  The IPIQ is the province wide training facility for all career firefighters in Quebec and roughly translates to: "Institute for the Protection Against the Fires of Quebec".  After class last year we toured several City of Montreal firehouses and discovered that the forcible entry tools provided by the department were somewhat lacking – 3 piece pinned halligans and pick head axes.  After the three days of training we left feeling a sense of pride and accomplishment that we were able to share our forcible entry knowledge and experiences with firefighters that were so eager to learn and put these techniques to use. 

We began to realize that we had made an impact when we received this photo from Captain Mart Corriveau of the Montreal Fire Department! 

 

 

 

 

 

Shortly after receiving the above photo we came across this photo from a fire in Montreal.  1 piece halligan, flat head axe, and the gap and cut technique that we review in our course!  The member on the right in the blue helmet had attended the class.  Thanks to www.coderouge.com for the use of the picture.

We were in invited back this year to conduct our "Beyond the Academy: Advanced Forcible Entry Ops" course for the academy staff as well as an open enrollment forcible entry weekend course.  We were pleased to hear that since our course last year, the City of Montreal has equipped each of its companies with a 1 piece drop forged halligan and flat head axe.  The instructors at the IPIQ facility have also begun integrating hands-on forcible entry training into their recruit school.  The academy purchased two door props from H & R Machine and now teaches students to force inward and outward opening doors.  Forcible entry scenarios are then integrated in everything from EMS training to RIT scenarios. 

We would like to thank the IPIQ for having us out to teach their academy staff  We are extremely proud that our teachings will now be passed along to every firefighter in the province of Quebec.  We hope that these techniques serve you well on the fireground and improve your abilities to serve your communities. 

Beyond the Academy: Video Training Series – Forcing Slide Bolts & Drop Bars

No comments

Here is the latest addition to our Beyond the Academy: Video Training Series.  This clip includes some tips and tricks for forcing slide bolts and drop bars on outward opening doors.  Feel free to add your comments, questions, or suggestions!  As always – no framing square needed!

 

Another Rex Tool Modification – By: Andrew Brassard

3 comments

Ever since my first blog on modifying a standard rex tool to be able to carry it in your pocket I have received lots of emails and had lots of questions about which modification (the pipe or the adz bracket). The reason why there is a debate about which one is better or more applicable is because I tend to like the adz bracket modification better because it allows you to rock the tool side to side and "walk" tough cylinders out off the door, with the pipe modification you loose the ability for the side to side movement.

The main reason that some guys like the pipe modification better is because in their company they utilise the wide adz halligan. So my latest project was to come up with a way to use either the pike or the adz to pull the cylinders. I have also seen on different blogs and websites  several other modifications by other people to give the ability to use both, this was usually accomplished by welding a pipe on the top of the adz bracket. This modification made the tool extremely heavy and awkward. Remember that this is a tool that you want to carry in your pocket most of the time, it should not look like something that a gas station should have the rest room keys attached to!

The first thing I did was cut the handle off a standard Rex Tool with a band saw. The next thing was I cut the length of the head down by 1'' to decrease the weight and size of lock puller, the head was now ready for the new staple. The new staple had to be made to accommodate the pike and the adz, the answer was far simpler than you might think. With the help of Jamie Hiller at H and R Machine I used a shop press to bow the centre of a piece of 1/4'' plate, the ends were then bent to fit the width of the lock puller. A MIG welder was then used to attach the bracket to the lock puller.

This modification gives you the best of both worlds, it allows you to be able to perform through the lock using either the pike or the adz. This new modification gives you a tremendous and light weight lock pulling option that you can keep in your pocket.

Slide Bolt Forcible Entry: Part 2

No comments

Click on the image to view or download the PDV version.

Slide Bolts – Exterior PDF

Slide Bolt Forcible Entry

No comments

Check out this info sheet for some forcible entry tips when dealing with slide bolts.  Feel free to print it out and post it in the firehouse.

 

 

 

 

 

 

Slide Bolts – Interior

Forcible Entry – The Bam Bam Tool – By: Paul Hoekema

1 comment

There are numerous ways to manipulate an American Series 2000 type lock to force entry (hockey puck locks with the key way on the rim of the lock not the face).  You can cut the lock ¾ opposite of the keyway, you can cut the rail above and below the lock and bend the rail out of the way, or you can use a pipe wrench and twist the lock off (if it doesn’t have a guard) just to name a few.  What happens if you’re on an engine and you don’t have all the tools that the truck carries to force these locks?  A simple solution to your problem is the Bam Bam tool.  The Bam Bam tool doesn’t take up much space and allows you to start forcible entry on American Series 2000 type locks until the truck arrives.  The Bam Bam tool utilizes a hardened screw to screw into the key way of the lock and a handle that slides along the shaft of the tool.  It is important to make sure that the screw is hardened.  If it isn’t then the screw may not screw into the lock cylinder, or when you go to force the cylinder the threads of the screw may strip causing the screw to come out of the cylinder without forcing the lock. 

To force the lock using the Bam Bam tool you need to place the screw in the center of the key way and begin to screw the tool into place.  It may take a few seconds to get the screw to bite into the cylinder, but once it does you want to screw it in about 3/16ths to ¼ of an inch into the cylinder.  It is about 4 or 5 threads deep into the cylinder.  You want to screw it in this deep so that you don’t strip the threads when you go to force the lock.  It is important to keep the Bam Bam tool as strait as possible while you are screwing it into position, so that the screw bites into the cylinder evenly giving it a better bite into the cylinder.  Once the screw is set you need to hold the Bam Bam tool with one hand while the other slides the handle back and forth along the shaft of the tool to force the cylinder and the pin of the lock out.  After the cylinder and pin is pulled out remove the lock. Don't forget to pull the pins after forcing the locks!

Using the Bam Bam tool would not be my first option for forcing American 2000 series type locks, but is something good to have in your bag of tricks when other methods of forcible entry can’t be used or are not available.  This method will not work on the American Lock 2500 Series.

 

Forcing Doors In Zero Visibility – By: Andrew Brassard

3 comments

Anyone who has ever forced a challenging door in zero visibility knows it can be one of the most difficult forcible entry challenges a crew will ever face, for those of you that have not… This challenge still awaits you.

Weather it is an apartment door on the fire floor of a garden apartment, the illegal basement apartment door in a private dwelling, or the door in a SRO on the floor above the fire the potential to need to force some tough door under arduous conditions is always present. The fact is that we as a fire service typically don't get much practice or direction on forcible entry techniques under favorable conditions let alone under zero or diminished visibility conditions. In this blog we are going to look at several different techniques for forcing entry under zero visibility conditions.

Size Up
Since we are unable to see size up is going to be tougher and normal and is going to be accomplished primarily by feel, both with your hands and the way the tool reacts on the door.

The first step is to feel the door with a gloved hand for any primary and secondary locks, bolt patterns, heat, etc. This will help establish a game plan of attack on the door. Remember you want to start with the highest lock first and work your way down so any heat or smoke behind the door will vent up and away from you.

After a rapid and thorough size up is complete you can begin forcing the door. You are going to GAP, SET, FORCE just like any other forcible entry operation, the only real difference comes from the setting the tool and more specifically the hitting techniques. We are going to look at 3 different hitting techniques that you can utilize to help you drive the halligan into the SET position.  

Double Tap Method
The double tap is more than just Rule 2 in Zombieland, it is a great method for forcing doors in smoky conditions. The double tap method works well in limited visibility situations but it allows a little to much margin of error for zero visibility operations to be an effective option. To perform this technique the axe firefighter lines up the axe with the halligan, he then taps the halligan lightly followed up right after by a more powerful hit. This small tap does a couple of things for both the firefighter holding the halligan and the firefighter hitting. First, it provides a small "practice" swing for the axe firefighter allowing him to build some muscle memory. Second, it gives warning to the firefighter on the halligan not to move because a more powerful hit is coming. Some firefighters like to use the double tap method all the time while forcing doors regardless of the conditions, it really comes down to preference.

Squared Off Shoulder
Most firefighters I talk to about the topic of zero visibility forcible entry say that they square the shoulders on their halligan forks off so that it will provide a striking surface without having the possibility of missing and striking the firefighter who is holding the halligan. This modification is not new to the fire service and I see firefighters modifying their tools like this all over North America, the problem is that if you are going to modify you halligan like this and then not practice the technique often and in realistic conditions then you might as well not even bother performing the modification in the first place. It can be challenging to perform this method and can take a tremendous amount of practice and patience. After the shoulders have been squared off the firefighter with the halligan can place the forks in between the door and the frame, with both hands on the back of the halligan the axe can be placed on the halligan shaft and slide it down to make contact with the squared off shoulder. Ensure that you keep a open palm grip on the back of halligan, if you have a firm grip on the adz or pike and the axe is brought back to far the blade of the axe could severely injury a finger… So keep a open palm grip. I like to keep the squared off shoulders for tight spaces or narrow hallways where you cannot stand behind the halligan to hit it.

One Handed Method
This technique in my opinion is the best method for forcing entry in zero visibility. The halligan firefighter takes their normal stance and hand position on the halligan with the exception of their hand closest to the adz, slide the hand closet to the adz more towards the middle of the halligan. The axe firefighter is going to take a kneeling position behind the halligan firefighter, the bottom hand on the axe is taken off and placed onto the halligan directly behind the adz. This hand is placed on the halligan to provide a point of reference for each swing of the axe. Remember to keep a loose grip on the halligan, your mission is not to impede or steer the halligan but to simple provide that point of reference. The next thing the axe firefighter can do to make life easier for them is to place the butt-end of the axe between their knees, this with help there swings tremendously by making the axe into a large pendulum. This pendulum action will help you deliver even and steady hits on target each time. Sometime with higher locks the firefighter will have to stand to swing the axe, the same steps are repeated with the exception of placing the axe between their knees.

 

 

 

 

 

Depth
How do you know when the halligan is in the set position? When you can see, we know that you want to drive it in until the crotch of the forks is level with the door stop but when we can't see we have to perform this by feel. An easy way to tell is by placing your thumb on the shoulder of the halligan then place three fingers along the side of the forks, the finger furthest away from your thumb should be level with the door stop. Slide your top finger forward and feel for the halligans orientation to the door stop. Not having the halligan set deep enough before prying is one of the biggest problems I see with zero visibility forcible entry, if the halligan is not driven in far enough it may pop out when it is pushed to the door.

The key to being able to force doors effectively in zero visibility and challenging conditions is to prepare for them through aggressive and realistic training. I recently talked to a close friend from a extremely busy urban department that just experienced a close call at a fire, one of the major problems that they experienced on the fireground was a delay of getting water on the fire due to a drawn out forcible entry operation. Crews were faced with a very difficult door in fairly horrendous smoke and heat conditions. After the fire crews talked about how they had never really been shown how to perform forcible entry operations under such strenuous and difficult conditions, the problem is that lots of firefighters tend to feel they don't need this type of training because they have never needed to force a real tough door under these conditions before. I use the analogy of RIT training, you only ever have to use it once on the fireground to make the training worth while.

I often get asked about injury while performing this type of training. I taught a recruit class for my department recently and I had the 10 recruits force hundreds of doors in zero visibility and in live fire conditions and never once did we even hurt anyones feelings. You need to ask yourself "what is the potential for a fireground injury if we DON'T do this training!"

Till next time stay safe!

Beyond the Academy Video Training Series – Engine Operations: Hydraulic Ventilation

No comments

Check out the newest Beyond the Academy Video Training Series. This one is entitled "Engine Company Operations: Hydraulic Ventilation with a Smooth-bore/Solid Stream Nozzle.

Many fire service members believe that a fog nozzle is the only nozzle that can be used for ventilation, and "prefer" a fog nozzle for that reason. These techniques show that a solid stream nozzle can be used as a hydraulic ventilation tool as well.  We do not entertain the "Smooth-bore vs. Fog" nozzle debate, but we do have our preference.

As Tom Brennan stated when asked about his preference: "A smooth-bore nozzle doesn't make a terrible engine company a good engine company, and a fog nozzle doesn't make a good engine company a terrible engine company!"

Regardless of which one you use, know your tools, the capabilities and the drawbacks. 

Feel free to discuss on this blog.

Tool Modifications 2.0 – The 8 Pound Force Axe – By: Shane Klug

4 comments

February 2011, I transferred to a ladder company, my first time being assigned to a truck.  Detroit ladder trucks typically have 6-pound pick head axes and 8-pound sledge hammers on them.  I tried both of them on the roof, and my tool of choice became the 6-pound pick head axe. I managed to get my hands on an 8-pound pick head axe and gave that a try. While the extra weight was great for smashing through roofs, the balance was VERY nose heavy, which made it harder to control and also very uncomfortable to carry.  Over the summer I was able to attend the Brotherhood Instructors Forcible Entry Ops class held in Independence Twp Michigan, where I used an 8-pound flathead axe, specifically the fire hooks unlimited 8-pound force axe.  I really liked the way the axe was balanced.  It was easy to control when swinging (in the forcible entry class) and seemed easy to carry.  Sometime after the class I purchased my own to use at work.  I decided to make some modifications, but with a twist, compared to what I had seen in the Brotherhood Instructor class.  First, I wanted to try and put the “notch” that allows the halligan forks to marry with the axe in a location that put both tool handles together, so I could get my hand around both tools. In Detroit, most front door forcible entry is performed by engine companies, so for me, I won’t be carrying a halligan much. So the more important modification I wanted was some kind of overstrike protection for my axe, as it would be used mainly for venting the peak roof of single family dwellings.  I had seen small sections of angle iron welded on the bottom of the axe head on the axes used in Gary Fire Dept (Gary, IN).  But they were welded with some space between the angle irons and the handle itself. In my opinion, this location for the over strike protection made it very difficult to carry the axe, especially while climbing up ladders etc.  So I had a friend TIG weld on some sections of angle iron below the head of the axe, but positioned them right against the handle of the axe, following the axe handle contour.  For those of you who have used an axe on a roof to smash a vent hole, you know that often times the axe head will smash through the roof deck and stop on the handle itself, over time break the axe handle right below the axe head itself.  Hopefully this modification will add some life to the tool for me.

 

I know this axe is called an 8-pound force axe, but I think the name sells this tool short.  As I mentioned above, I don’t do the majority of forcible entry, as the engine companies often do the front door and Detroit truck companies only carry one halligan, which is mainly carried by the boss of the truck.  My main objective as a deckie on the back end is to make the roof and ventilate. The vast majority of the time, I’m using this axe to open single family dwelling roofs.  When used in tandem with a saw (chain or rotary), I can use the flat side of the axe to “turn” the boards over on the rafters after they have been cut.  Of if there is no saw available (or the roof doesn’t lend itself to using a saw), I can use the blade side of the axe to start a hole (especially on roof decks that have multiple layers of shingles), then can flip over to continue smashing the roof boards.

       All in all, this axe is fantastic for forcible entry and makes a great tool for vertical ventilation. With the addition of the over strike protection, hopefully the tool will have a long service life opening roofs!

Through the Lock – Pivoting Deadbolt & Hookbolt

No comments

Through the lock forcible entry is a quick and easy method of gaining entry into doors locked with pivoting deadbolts and pivoting hookbolts.  This skill is easier than many believe.  Click on this through the lock info sheet to download a PDF version.  Feel free to use it, print it, and share it with your crews. 

 

Coordinated Ventilation – Part II by Nate DeMarse

No comments

I stumbled upon a couple videos that drive home points made in the earlier Coordinated Ventilation post. These videos clearly show answers to previously asked questions, and bring up some new discussion tips as well. This is precisely how we should be training at drills and training burns. I don't know where this department is, but they are a class act in training!

Video #1 – The OV Position:

In the first video, we see an Outside Ventilation (OV) firefighter in the correct position to horizontally vent the building opposite the attack line's advance. Note that at the very beginning of the video, the Nozzle Team is advancing the hose line THROUGH THE FRONT DOOR and to the seat of the fire. The door is forced, and they are moving in when the windows are taken.

The firefighter is off to one side of the window, and takes the window located furthest from him first. This assures that he will be able to vent both windows without delay. If the window closest to the firefighter is vented first, and fire vents from the opening the second (furthest window) may have to be abandoned. This is especially true if operating on a portable ladder or fire escape. 

Video #2 – Points & Pointers:

I am not certain, but I think the video below is another angle of the same video above (a very rare occurance in our profession). If it is not the same fire, we are going to use it like it is for the purposes of driving home a point.

As I stated in the comments in Part I, "We should also wait if the line is delayed in getting into position, charged and READY TO MAKE THE PUSH on the fire. There is a vast difference in a line being there, a line being charged, and all of the members masked up and ready to push in." This video starts with a charged attack line, but the door hasn't been forced. If the OV takes the windows prematurely, this fire will continue to spread and grow as the line is not ready to advance. After entry is gained, you can hear the officer telling the OV to "take that glass".

Entering the Building Side-Note:  At the :35 second mark, you will see the camera move to the front stoop of the house. Note the visibility at the floor level! You can see nearly ALL THE WAY THROUGH THE HOUSE. Yet nearly every single firefighter that entered the building entered either standing or slight crouched with their head in the smoke, unable to see ANYTHING! I will reiterate at this point that I am not beating up on this department, THIS HAPPENS EVERYWHERE!!

Take a second after the door is forced to put your face piece directly on the floor and look UNDER the smoke. This requires you to get on your knees to accomplish. The nice thing about taking a look at the floor level is that you have to physically, consciously make a decision to stand-up to enter after you look.

Here are a few other benefits that stem from taking a few seconds to get low and take a look:

  • You allow the heat and super-heated gases that have built up in the sealed building a few seconds to "blow" and push over your head. This in turn will cause the smoke to lift off of the floor, and allow for the following:
    • You will be able to see a victim lying on the floor 10 feet or further inside the doorway, at that point you can say you conducted a rescue instead of tripping over someone and pretending that you rescued them! The Medal Ceremony will sound supurb, but you will know the truth!
    • You will be able to get a room, floor or apartment layout.
    • You will be able to see the glow of the fire on the floor, or the fire itself. You will know that it is on the right side of the hall, three doorways down.
    • You wlll see the large hole in the floor five feet inside the house and not fall into the basement and promptly call a "Mayday" within seconds of entering the building.

You will know all of this information at the front door, without walking (not searching) blindly. Then, because you are already on your knees conducting this vital size-up skill, you will enter the building safely on your knees, crawling towards your objective(s). When we couple the skills listed in this side-note with the OV performing those tasks in the correct position and the correct time, you will have the opportunity to gather vital information before entering.

THESE TASKS ALLOW US TO BE AGGRESSIVE AND SAFE! 
(and yes, those words can be used together)!

Forcible Entry Side-Note: The Forcible Entry team did a good job on the door. If you look closely, on the fourth swing the Striking FF nearly misses high with the axe. With hand placement so close to the axe-head, just a little more of a miss could have caused a crush injury. Believe it or not, in our travels this is the most common cause of injury in forcible entry (almost always resulting in at least one broken finger). To remedy that concern, This video (one of our first created nearly 2 years ago) shows safe striking techniques. Additionally, Brotherhood Instructors, LLC axes now have our company markings (colored electrical tape) 6"-7" below the head of the axe. Any firefighter using our axes know that if they place their top hand where the tape is, their hands are in the safe zone. Again, this is a very common injury and very rarely do we get a chance to catch forcible entry tools and members practicing their craft.

I think this fire department is doing a great job in getting their training done as we operate. Far too may training burns just walk members through the motions, leaving them with a false sense of security of what a real fire will be like (i.e: setting themselves up for failure). This department has their members on the radio, and conducting coordinated ventilation and fire attack. These videos left some open some great discussion points using realistic training and errors that occur on EVERY fireground!

Feel free to post comments, questions or concerns. We are all here to learn so let the learning commence!

Respectfully,
Nate DeMarse
Co-Owner, Brotherhood Instructors, LLC.

 

Duckbill Lock Breaker – By: Andrew Brassard

3 comments

Nowadays firefighters tend to become over reliant on saws during forcible entry operations and often forget some of the most basic of fireground tools. The Duckbill Lock Breaker is one such a tool that has become a forgotten tool that tends to sit in a compartment on the truck. But what about the times when, the saw does not start? Or you have to change the blade? Or you have to remove locks inside of a building where the saw will be choked out by the smoke? The duckbill is a tremendous secondary tool for these situations.

The Duckbill Lock Breaker works by driving the lock shackle off the body of the lock. The lock breaker will remove an American 700 Series Lock with no problem, in fact there are very few locks that can not be defeated by the lock breaker. One lock the can withstand the forces that can be applied with the lock breaker is the disc type lock. If a disc type lock is present a different forcible entry method should be utilized.

 

The Duckbill Lock Breaker is a single functioning tool, meaning it's only function is to force entry into padlocks.

The duckbill is made of soft metal, usually brass. The reason for making it out of soft metal is so that as it is driven down in between the padlock body and the shackle the lock will "bite" into the soft metal of the wedge and hold it's position until it is struck again. Every time the lock breaker is struck it is driven down a little further into the lock, this places more and more pressure on the lock until it finally fails. If the wedge was made out of a hardened metal it would simply bounce out every time it was struck.  

To use the Duckbill Lock Breaker, simply place the wedge into the lock. This is where mistakes get made! The only way the duckbill will work is with the top edge of the wedge on the shackle and the bottom edge of the duckbill on the body of the lock, do not put the duckbill into the lock with the top and bottom rails on both side of  the shackle! Once the lock breaker is in place use the 8 lbs forcible entry axe or a 12 lbs Maul to drive the duckbill into the lock, continue driving it in until the lock fails. It is that simple!

So dust off the duckbill lock breaker, dig it out from the compartment, or buy one to include to your forcible entry arsenal. It is a great tool that can prove to be extremely valuable on the fireground.

 

 

 

 

Coordinated Ventilation

6 comments

Take a look at these two videos for a great example of coordinated ventilation.  The outside vent (OV) firefighter on the fire escape waits until the line is putting water on the fire to take the windows.  Doing so helps the engine make the advance into the fire area a little easier.  Waiting until the line is ready will ensure that you do not prematurely feed the fire additional oxygen and possibly trap firefighters searching ahead of the line. 

 

 

Electric Roll Up Gates – By: Andrew Brassard

No comments

Not all forcible entry has to be forcible, in some cases a little knowledge and some finesse will get the job done quicker than some more traditional methods.

One such instance is Electric Roll Up Doors and Gates.  With a little bit of knowledge and a screwdriver entry into these gates can be very fast with very little force. Electric Roll up Gates are most commonly found in my area on loading docks, garbage rooms, and on the occasional roll up gate. These electric door openers are usually found mounted around 4' off the ground directly beside the door that it opens. There is a key way on the control panel.  This key way controls the door going up and down. The key way is often a standard mortise lock cylinder, on the back side of the cylinder. A large pivoting arm is bolted to the key way. When the key is inserted and turned the pivoting arm will twist and hit a limiter switch to either roll the door up or down.

 

 

 

Forcing entry
Forcing entry into the door usually does not require very much force at all, the only tool that you need is a screwdriver in most cases. The first thing you want to do is undo the screws in the four corners of the face plate. I have been told by friends that they have encountered security screws in these from time to time, I have never encountered these security screws. Most of the time standard Philips, Robertson, or Slot headed screws hold the face plate on. Once the screws have been removed the face plate will need to be pried off with a halligan or Rex Tool. The reason for this is that the pivoting arm on the back side of the cylinder hits small tabs on the  edges of the electrical box. The tabs are why it says on the front of the lock face that you must have the key in order to open the lock, when the key is inserted into the key way and it is turned the pivoting arm turns and is able to fit past the tabs on the electrical box. To pry the face plate off is not difficult, these tabs on the electrical box are light gauge galvanized metal that will bend quite easily with a little pressure with a prying tool.

Operating the gate
Once the face plate has been removed and pried out you can operate the gate. Directly behind the pivoting arm is a limiting switch with a simple button to operate the gate up and down, there is one button on each side of the lock cylinder. You can simply use your finger (or a pencil if it makes you feel more comfortable) to push the button and activate the door. If you look at the face plate you may be able to tell what side the limiter switch is for "Up" and what one is for "Down" by the words on both sides of the lock cylinder. If no words indicating what side is "Up" are present simply try pushing one side, if it does not work it means that it is the other side. Keep in mind that you are dealing with live electrical wires so extreme caution must be taken not to touch any wires, if you use the proper techniques and give any electrical component the respect it deserves than that should not be a problem.

Also remember to take a thorough look at the gate and properly size it up. If there are additional locks on the door such as traditional pin, hasp, and padlock assemblies, then these locks must be removed before this entry method can be performed.

In some instances these gates are also locked from the inside or the electrical switch no longer works, in these instances the gate or door will have to be cut with a power saw.

Also be sure to check with your departmental SOP's and SOG's before performing this entry method, some departments have policies against members touching an electrical equipment such as this.

This is an extremely quick and effective method for forcing entry and it causes very little damage. The best way to prepare for these types of forcible entry situations is to pay a visit to the company in your city or town that install these electric gate openers, ask them to run you through the most common types that they install in your area.

Till next time, stay safe!

More About Nozzles – By: Mike Kirby

4 comments

This is a debate that plagues the fire service. Most of the personal "experience" or "knowledge" from this debate stems from lack of knowledge or understanding of the simple principle that GPM (properly applied) puts out fires. Some believe that pressure is what we should be concentrating on. Firefighters start out in their "firefighter" schools, where ever that may be, and learn about the nozzle they have there and then go to work somewhere and only learn about the nozzle they use there or the one that that person tells them is the end-all-be-all of the fire service. Few firefighters are aware of what is available to them, what each one actually flows under live conditions, heat absorption characteristics, etc. If all you have ever used is a combination nozzle, you have probably never flowed a smooth bore hooked to a GPM gauge to see the flow and experience the difference in pull back pressure.
 
The problems with all new tools / nozzles / methods of going to work is that it is change and fire fighters have to be more resistant to change than any other culture or group of people on this planet.

We need to make sure we educate all of our fire fighters on what they are carrying and how much water it puts out at varying pressures and with various lengths of hose. I'm not a personal fan of the adjustable or combination nozzle whether its a fixed gallonage or automatic. This nozzle has been used in the 5 fire departments I have worked for. Its generally not the tool, but how you use it I always say. Fires still go out in these 5 places. Some maybe not as effectively as others due primarily to GPM delivered. I personally prefer the smooth bore nozzle. It is simple, won't clog and is inexpensive. Next I prefer the vindicator. Both the smooth bore and vindicator can put out a very high GPM flow from an 1-3/4" fire line. One costs about $150 and the other around $800. The CFD recently has started phasing in an Elkhart Chief 250 gpm @ 50 psi to replace the outdated Task Force Tips. The TFT's were automatic type nozzles with a complicated pressure control mechanism. These nozzles just don't work right anymore due to the age, wear and lack of maintenance on the internal pressure control mechanism. The Chief nozzle selected flows comparable to the Vindicator, but gives the "hard head" fire fighter the option to have a fog or straight stream. The reasons the "hard heads" don't like the vindicator ring true for a smooth bore as well. "I need the "fog" stream to ventilate". We made sure we found a combination nozzle that allowed them to have fog for ventilation and other scenarios that also flowed a lot of GPM from a 1-3/4" fire line.
 
I'm an advocate of I don't care what you or your department uses, just know its limitations, how much water it can put out with it in GPM and how it reacts to line kinks, long lays, reduced pressure situations, etc. You need to do this with a flow meter. If you cant get a flow meter, ask a sales representative to bring a nozzle out for you to demo and flow and while flowing that nozzle, flow your current nozzle alongside of it.
GPM properly and rapidly applied puts out fires. There is no greater live saving action on the fire ground than to put out the fire and stop all the bad things going on inside the building. (sorry truckers….)
 
Mike Kirby- Cinncinati Fire Department Engine Co. 12

Changing Saw Blades – Diamonds are a Firemen’s best friend too – By Grant Light

No comments

 

Over the past few years there have been some big changes in the type of circular saw blades used by fire departments across the country.  In the past almost all of the metal and concrete cutting was accomplished with fiber wheels made of a sacrificial material such as aluminum oxide or silicon carbide.  The biggest problem with these blades was that they got smaller as you cut, causing you to change blades during a rescue and at times not allowing you the depth of cut needed to get the job done.  The potential for blades to fly apart during operations was also a big safety issue.  You had one blade for metal, one for concrete and at times one for stone.  Just that fact alone required a quick decision about the work to be done and in some instances quick blade changes were required before cutting could begin.

Just like everything else in the fire service, saw blades have changed dramatically as new technologies have moved from the construction industry to the rescue services.  Diamonds are where that technology has taken us.  Many different types of diamond blades are available but we will look at two, Segmented and Vacuum Braised.  Segmented blades have a diamond impregnated segment attached to a steel wheel.  They were originally designed for cutting concrete with imbedded rebar.  They moved to the fire service through US&R teams and are used by many companies to cut metal during forcible entry operations.

The newest additions to diamond technology are the Vacuum Braised blades.  They have very high quality diamonds attached directly to the steel wheel.  This removes any chance of a diamond segment coming off the wheel and becoming a projectile during operations.  These blades can cut an extremely wide range of products such as Hardened locks & shackles, hockey puck locks, security gates, re-bar, chain-link fence, stucco, concrete, block, brick, stone, asphalt, wood, drywall, car doors, ductile iron, cast iron, angle iron, black iron, schedule 40 &80 steel pipe, plastic pipe, 2x4s and plywood.  These blades will do all this without reducing the depth of cut and outlasting fiber wheels 100:1 or more.  During training at a scrap yard we cut through a fiberglass roof on a conversion van, which was backed up by 4 layers of OSB plywood and then turned and cut the class 3-trailer hitch off the rear of the vehicle.   We were using a Desert Diamond vacuum braised blade and it didn’t skip a beat.  The ability to grab a circular saw and cut just about anything you encounter is a welcome change from the blades we used just a few years ago.  These new blades have a higher upfront cost but their ability to cut a wide range of materials, remain a constant diameter and outlast any forcible entry cutting scenario you might encounter make them a smart choice as you move forward into the future of circular saw blades.

Hit, Hit, Hit Part 2 – By: Andrew Brassard

No comments

In the last article we talked about ensuring that the striking firefighter has their top hand at least 6" down from the head of the axe.  This is to ensure that any missed strikes don't crush the striking firefighters fingers.

Now we are going to talk about where to place your bottom hand and how to position your body for optimal striking during conventional forcible entry operations.

Just like the placement of your top hand, your bottom hand placement can be critical to a smooth forcible entry operation. For some reason, lots of firefighters want to choke their bottom hand up to around the middle of the axe.  This grip can lead to problems during forcible entry operations. What tends to happen when using this type of grip is that as the striking firefighter swings the axe, the butt end of the handle digs into the firefighter holding the halligans leg. The momentum of the axe being swung usually doesn't stop once the butt end of the axe handle bumps the firefighters leg.  The momentum tends to carry the axe through the swing but drastically off target. This obviously can lead to missed hits and the potential of injuring a member.  Instead, place your bottom hand down at the bottom of the axe just above the fawns foot. This will allow you to be more aware of where the butt end of the axe handle is.

 

Don't be a Fool…. Cross your Tools
Another very common striking  mistake is not crossing your tools. The optimal striking position for the axe is to have it crossing the adz of the halligan and not in line with it. The reason for crossing the tools is that it increases your striking surface to allow for small inaccuracies. With the axe in line with the adz it leaves very little margin for error for the striking firefighter, if he is off the mark by only 1" this could cause a glancing hit on the adz and cause the halligan firefighter to be struck. If the axe and the adz of halligan are crossed it will increase your margin of error by giving you 2" up and down and 3" left to right leeway in your swing.

Keep your Eye on the Ball
When I was a young kid my father was teaching me how to catch a baseball and the first thing he said was "keep your eye on the ball", this principle applies the same to forcing a door. You should always try to make yourself eye level with the adz, this will make your swing much more accurate. Depending on the location of the lock being forced, you may have to take a knee, crouch, or you may be standing straight up, but for the majority of locks that are located in the middle of the door the striking firefighter should take position on their knees.

These small tips will help you be more proficient during you forcible entry operations.

Until next time, stay safe.

Hit, Hit, Hit – By: Andrew Brassard

1 comment

 

 

I have been teaching forcible entry for almost 10 years, in that time I have seen a few injuries. It sometimes comes with the territory: bumps, bruises, and the odd black finger nail have happened when both members of the forcible entry team are not on the same page. One of the simplest mistakes that I have seen firefighters make that leads to injuries is holding the axe too high on the shaft. A lot of firefighters are thought to hold the shaft of the axe directly below the head. In my opinion this is an incorrect grip.

The reason that this grip is not favorable is because if the striking firefighter is off the mark with the swing by only a few inches the can crush their fingers between the shaft of the axe and the halligan adz. I have seen this on several occasions and a couple of times it has led to a black finger nail or a broken digit. This is a serious problem not only because of a member getting injured but on the fire ground the forcible entry operation is halted which could cause significant delays in entry, water on the fire, ventilation, or commencement of search and rescue operations.

To avoid this, ensure that your members keep their top hand at least 6" below the head of the axe. Lots of companies, to ensure that there members do not forget this, place there company identification colors or number at least 6" down from the axe head, this will be a subtle reminder to keep your hand down and it will also build company pride and ensure no other company walks away with your tools.

Cutting the Locks

9 comments

Brotherhood Instructors believes in having multiple plans in mind for any forcible entry situation.  A back-up plan for forcing an outward opening door can be cutting the locks.  We prefer to gap the door away from the frame and cut the throw of the lock as opposed to cutting the door, known as the "bird beak cut".  The bird beak cut seldom works since it is very difficult to cut completely through the door due to the door frame getting in the way. 

 

 

 

 

 

 

 

 

If you decide to cut the locks, gap the door away from the jamb using the halligan or axe.  Start the saw blade spinning at a low RPM to make a groove in the bolt of the lock and then throttle to full RPM to complete the cut.  This is an especially helpful technique when dealing with foot bolts.  Having the power saw set up in the outboard position will allow the saw to better cut the foot bolts.  Click here for our previous blog on foot bolts.  Be sure when cutting the bolt of any lock to cut as close to the door as possible.  This will ensure that the lock can not re-latch once the tool holding the gap has been removed. 

 

 

Brotherhood Instructors class in Wildwood NJ

No comments

Brotherhood Instructors, LLC. will be presenting our 8-hour hands-on "Beyond the Academy: Engine & Ladder Company Operations" class on Thursday September 15, 2011.  This course is hosted by the Cape May County Fire Chiefs Assn. – Click here for registration information!  Sign up now, don't get left out!

Click here to see pictures from last years class!

Beyond the Academy: Engine & Ladder Company Operations consists of parts of our Beyond the Academy: Engine Company Operations & Beyond the Academy: Ladder Company Operations classes.  Check out these videos for a quick overview of the course material.

 

 

2012-04-21 – Sergeant Bluff, IA – BtA Machinery Rescue – Flier & Registration Form

Beeton MIM

Fergus MIM[1]

Mt Holly Flyer2

Antonia Flyer2

Course Catalog – Email Version

Checking for Extension

No comments

Firefighters assigned to the roof play a critical role in numerous fire ground tasks.  Vertical ventilation, building information, and checking for fire extension to the cockloft or attic space are just a few of these tasks.  Vertical ventilation and checking for extension can often be done together by taking a skylight and opening the skylight returns.  Click here to see our previous video on that topic.  When the roof is pitched or there is a void space along the parapet fire can easily extend through these spaces. 

Many times the roof is pitched downwards from the front of the building to the rear in order to allow drainage at the back of the building.  If there is a fire in the rear of the building and the roof is pitched downward from front to rear an inspection hole should be made towards the front of the building.  Throughout the operation monitor this inspection hole for heat, smoke, and fire.  If fire extension is found or expected, enlarge the opening and radio the findings to your company officer or incident commander.  This further illustrates the importance of checking for fire in the cockloft immediately inside the entrance of a commercial building if no one is assigned to the roof.

Roof void spaces are a common path of fire travel.  Firefighters assigned to the roof should place inspection cuts in void areas if there is any suspicion of fire in the cockloft or voids.  Triangular void spaces along the parapet are very common in residential and commercial buildings.  Usually these void spaces conceal structural members used to support the parapet.  If fire is found in this area be sure that no one is on the sidewalk below the parapet.  Here are a few pictures of this construction feature courtesy of Keith Morse from the Woodland Twp. NJ Fire Dept.

 

 

 

 

 

 

 

 

 

 

See more from our Beyond the Academy: Ladder Company Operations class

Video – The Quick Louver – By: Jamie Morelock

No comments

Check out the latest addition to the Brotherhood Instructors, LLC. Video Training Series.  Instructor Jamie Morelock reviews the vertical ventilation tactic known as the louver cut.

Tactical Discussion: Apartment Fire w/ Critical Decisions by: Nate DeMarse

8 comments

We first saw this video on Backstep Firefighter. An excellent video surfaced this week that addresses some very critical decisions that must be made in seconds at this early arriving apartment fire in downtown Mamaroneck, New York.  I want to preface this discussion by saying that the Fire Department in Mamaroneck did an OUTSTANDING job in getting several things accomplished simultaneously with very limited manpower. They were confronted with a very complex situation, including a complex laddering problem that they overcame without hesitation.

It appears that the first due engine has arrived to a heavy fire condition in at least one room on the second floor of a three story apartments over stores "downtown-type" building that is common across the entire North American region. In reality, this fire could have happened in nearly ANY TOWN in North America. So since it COULD HAPPEN in your town, here are a few questions to discuss the incident.

There is a visible victim at the top floor window in obvious distress. As we say at every Brotherhood Instructors, LLC course, I am going to step out of my "FDNY Manpower Fantasy World" and attempt to stir a discussion that applies to the other 95% of the firefighting world.  You are arriving with an "now-standard" engine staffed with THREE (including the boss). If you have a total of four, you are extremely lucky, and feel free to answer accordingly. The next due engine and/or truck is 4-5 minutes out.  How and when are we addressing the following concerns from the video:

1) Do we stretch the line to confine/extinguish the fire first or do we go for the ladder rescue? Why? What are the pros and cons of each?

2) Can you split your company to get both accomplished at once? If so how? What are the implications?

3) What sized portable ladder (if it was available on your engine) would you use to reach the 3rd floor sill?

4) What are other options to the portable ladder in the front?

5) What size attack line are you pulling to attack this second floor fire?

6) What are the forcible entry concerns at this fire? Type of door, locks, etc…?

Please copy and paste the questions into your reply below, and answer using your name & department. Keep in mind that we have a lot of young firefighters on this blog that read our posts  to learn, so if you have something throw it down even if you think it is very basic. To the young guys: DON'T BE AFRAID TO ASK QUESTIONS!

Now take a look at the photos below (bing.com, birds-eye-view) for some added size-up discussion. Unless you were intimately familiar with this building during inspections, EMS runs, water leaks, etc… this building can cause you some complex problems.

1) The fire is located on the 2nd floor, but the 3rd floor is only about 1/2 or 3/4 the depth of the building. Does this now become a top floor fire? How are you getting to the lower level (2nd floor roof) in the rear? How would you communicate this?

As a Roof Firefighter, in my opinion your game plan has now changed. I would be expecting to go up there and force a skylight, scuttle and/or bulkhead and do a perimeter survey. This won't be the case at this job. This is a perfect scenario to drive the point home of crawling or probing with a tool in front of you in a limited visibility condition. If you do not in this case, you can take a 1 story fall to the rear roof, rendering you injured or worse.

2) Note the potential VES opportunity that may be available on the Exposure 2(B) roof. It appears from the overview photo that the window in the A-B (1-2) corner may lead to the same room that the victim is trapped. There are also similar VES opportunities in the rear (2nd floor roof) if needed.

Feel free to add further questions or stir discussion. Remember, we strictly moderate our blog discussions. Keep it professional and to sign your posts. NO UNSIGNED POSTS or posts that simply bash the department (which would be very hard in this case) will be allowed.  Stay safe!

 

 

 

Pulling Mortise Lock Cylinders

No comments

Mortise locks are commonly found in commercial and residential buildings.  Many mortise locks are installed with a trim plate on the door that has predrilled holes for the lock cylinder and door knob.  Keep in mind that these are trim plates, not cylinder guards.  These trim plates are hollow and can easily be dented in to allow the lock pulling tool a better bite on the cylinder. 

 

 

 

 

 

 

 

 

 

After verifying that the door is in fact locked, dent the cylinder guard in with a tool to expose the sides of the cylinder.  Once this has been done, set the lock puller onto the cylinder and give it a few hits to set it in place.  Now pull the cylinder.  With this type of lock it is sometimes helpful to rock the lock pulling tool back and forth to loosen the cylinder up.  After the cylinder has been removed, you can proceed with your through the lock operation. 

 

 

 

 

 

This video demonstrates rocking the tool from side to side to assist in removing the cylinder.  Be sure to always have your irons available in case the through the lock operation fails as in this video. 

Why Search That Building – By: Scott Brown

3 comments

We respond to building fires daily in the fire service and the assignment of primary search has taken a back seat.  Primary search is a critical benchmark and essential task to be completed.  This task should be simultaneously completed with line placement and proper ventilation!  Remember that line placement and primary search save lives; isn’t that why we are here?  It is not justifiable to state that either is more or less important on the fire ground.  Manpower now a days is difficult to find, but is it? We are expected now to do more with less with all of the emphasis on EMS. Only we can make this change, by us stepping up and making a stand for what is right for our safety and the communities’ safety. You have to get certain duties completed on the fire ground, but more importantly they must be completed in a timely manner. Waiting to be assigned or not starting a primary search will hinder the true operations and meaning of the duty at hand. If this is how you operate, then maybe we should revise the terminology to body recovery search.

Where do we start and what do we look for?  First thing first; SIZE-UP! You can not have the same search thought process for a single family dwelling as you do a 200X200 commercial building!! Your size-up will tell you a lot of information on what is going on inside the building, and give you indicators on where you need to be first to make most of your time. Size-up for a primary search is essential and needs to be completed on the transmission of the alarm. Building construction, we need to search according to the building type. The days of fire school searching, hand on ankle, and always doing a right hand should be gone. We are not going to complete any kind of search in a timely manner. Line placement, with out a line placed and into operations we will not be as effective doing a primary search. Remember, the truck company is only as aggressive as the engine company. Fire conditions, this will tell us how far we can go with out putting ourselves into unnecessary harm. Remember, there is no reason to search a room that is on fire. If we can’t take the heat with all of our PPE, then what chance do they have? So take your risk benefit and weigh it out.

What if every one is reported “out”; well how sure are you? Maybe a neighbor attempted to go inside and look for their neighbor thinking that they are still inside. Yes, that has happened, and can easily happen to us right now today. Is the structure clear until we clear it? It would be heart wrenching to know a victim possibly had a chance, but we decided not to commit or worse not complete this task until after the fire is knocked down. Remember, your size-up will give you good indicators for savable victims.  Gaining all of the essential information will dictate how advance you will commit for savable victims.     

What do we look for once inside?  YOUR NEXT EXIT!!  This is for you and your members.  We spoke about the size-up on the exterior, but don’t forget about your interior size-up. Size-up everything you do, building lay-out, smoke condition, heat condition and listen to the radio for other benchmarks.  These items make or break your commitment to the interior.  This is where we see a lot of firefighters get into urgent and/or mayday situations.

The other reason that we search is to find the fire, if you have done this there are things that need to be completed. First attempt to check the fire, by closing the door, maybe hit it with the water can if it is a must. Remember though, it is not there for that reason. Then, get on the radio and call the engine’s officer and tell them where the fire is. You can relay, how far of a stretch, up / down stairs, which side the structure. Make the line’s job a little easier; they will make your job easier. The engine should be searching the fire room or rooms. You can also secure the utilities if you happen to come across them.

Primary search should have a minimum of one firefighter and one officer. But, this can be building dependant and life hazard dependant. Maybe we need to send the entire company inside to get the job done? All to be decided on your size-up, as you arrive on the scene. Tools are essential and should be mandatory that all personal have the basics. I will start off with the irons; we need to gain entry for us and the line. Water can, this is not to be cowboys and put the fire out, but is 2.5 gallons of water for our safety. You will be amazed what a water-can will do. Yes, this is heavy 25-30 lbs, but the value out weighs the true weight. Remember, that you do not need to carry the water can, when you are completing the search, but you can drag it. 6’ Hook, this can provide an excellent extension of your arm for searching. The hook can also assist in providing relief to companies trying to make that final push down the hallway and are being hindered by heat. Thermal Imaging Camera, this has many options, look for victims, check fire conditions, navigation, structural conditions, and accountability of crew. Remember that the TIC has faults and is man-made and will fail. The TIC also has many false positives, and you still must be aware of your surrounding the old fashion way. Some additional tools to consider for large square footage buildings, but can be used in any type of building. Rope bag, my area runs 200ft of search rope.  This is due to our normal first due area, and yours should reflect the same. Hydra – ram or Bunny tool can be used if forcing a large amount of doors, remember your basic forcible entry skills. Yes this is a lot of equipment to carry, but remember if you get where you are going and there is no need to utilize the hydra-ram or rope bag; then place that tool in a safe-refuge. In all these tools are just the basics and give you good start. I have assumed that PPE , radio, flashlight(s), door chocks are already in place with you.

Starting your search, use the irons (if needed) to make entry into the most appropriate door to begin your search and for line placement. Sow down for just a few seconds, let the building breathe.  This could show what the conditions are inside! Before you enter the building / door bend over and place your face on the ground and look in, you might get a full view of the layout of the room. You might find a victim, and be able to go right to them. Begin your search using the left or right hand method, but there is no reason to search directly behind each other. Spread out, but staying within voice range, spread your body out. Remember, we are not looking for pennies, we are looking for bodies. There is no reason to search the top of a dresser, or behind a TV. Where are we going to find victims, in bed, closets (kids) and the path of an exit way. Yes, there will always be exceptions to the rule, but remember PRIMARY SEARCH is to be quick. Check for bunk beds, remember to look around, is there toys? Maybe you are in a kids’ room. A nice bench mark on the fire ground is 4-5 minutes into the search. What is your status, are you completed? Are you delayed and command needs to get more search companies?

Primary search needs to be a quick and thorough. This assignment should be automatic, and companies on the first alarm should know that they are assigned to do this, so they are prepared with the most important tool, their brain. Bench mark at the 5 minute mark, most residential searches can be completed in this time. You can do this with aggressive hands-on training, and knowledge. Take your tools with you every time, if you do this, when the real work comes in, it will be second nature to carry everything. Also take care of your tools, clean them, and maintain them. All this can be done at truck check, at the start of your shift morning or night. If you don’t do a search in a timely manner find out why, is it manpower, lack of training or some other issue. Many of these items can be addressed with a little bit of research. If you are not beginning primary searches upon arrival and you are waiting 20-25 minutes to do so, it is not a primary search. You are expected by your tax-payer to perform these functions, don’t let them down. Because you don’t work for a “Big city”, is no excuse.